Three Easy Steps to Choosing
The Correct Cable For Your HMI:
1. Locate your Controller Manufacturer in the left hand
column of the table. 2. Then locate the row with your Controller
Model. 3. Follow along that row to the right until you are
underneath your particular HMI Series or HMI Model.
Important: If it is blank, it means that Maple Systems
does not provide a cable or instructions for that particular controller and
HMI. The word, “instructions” means that we do not make the cable
but the instructions will show you how to do it yourself.
All cables are made to order and are non-refundable so please
make sure you have ordered the proper cable for your unit. If you are unsure,
contact Customer Service for assistance.
This information is subject to change without notice.
Communication Cables (by Controller)
Click a “ ” button
below to place an item in your shopping basket. To continue shopping after that, simply click the “ ” button on your browser window.
|
Controller Manufacturer |
Controller Model |
Comm. Type |
Controller Connector Type |
HMI500 Series |
HMI5000 Series |
HMI504T
&
HMI5043N
|
|
ABB Drives
|
ACH550
|
RS-485
|
Leads
|
7443-0171-5
|
|
|
|
AC Tech
|
Lenze 940
|
RS-485
|
Leads
|
7443-0172-5
|
|
|
| Allen-Bradley |
ControlLogix |
RS-232 |
DE9S |
7443-0004-5 |
7446-0004-5 |
7444-0004-5 |
| MicroLogix 1000, 1100,
1200, 1500 |
RS-232 |
DIN 8 Pin |
7443-0040-5 |
7446-0040-5 |
7444-0040-5 |
| MicroLogix 1400 |
RS-232 |
DIN 8 Pin |
|
7446-0186-5 |
7444-0186-5 |
| MicroLogix
1500 |
RS-232 |
DE9S |
7443-0004-5 |
7446-0004-5 |
7444-0004-5 |
| PLC-5 (DF1
port) |
RS-232 |
DB25P |
7443-0006-5 |
|
7444-0006-5 |
| RS-422 |
DB25P |
7443-0007-5 |
7446-0007-5 |
7444-0007-5 |
| SLC500 (DH485
port) |
RS-485 |
RJ45 |
7443-0083-5 |
|
7444-0083-5
|
SLC5/01, SLC5/02,
SLC5/03, SLC5/04, SLC5/05 (DF1 port) Note
1 |
RS-232 |
DE9S |
7443-0004-5 |
7446-0004-5 |
7444-0004-5 |
| SLC5/01, SLC5/02 (KE
Module) |
RS-422 |
DE9S |
7443-0005-5 |
7446-0005-5 |
7444-0005-5
|
|
Animatics
|
SmartMotor Series
|
RS-232
|
DE9P
|
7443-0095-5
|
|
|
| Aromat |
See
Panasonic |
|
|
|
| Automation
Direct |
See
Koyo |
|
|
|
| Baldor |
Motion
Controllers |
RS-232 |
DE9S |
7443-0082-5 |
|
7444-0082-5 |
| NextMove BXII |
RS-422 |
DE9S |
7443-0133-5 |
7446-0133-5
|
7444-0133-5
|
| Flext DriveII, MintDriveII |
RS-422 |
DE9S |
7443-0135-5 |
7446-0135-5 |
7444-0135-5
|
| Bristol
Babcock |
ControlWave |
RS-232 |
DE9S |
7443-0124-5 |
7446-0124-5 |
7444-0124-5 |
|
Network 3000
|
RS-232
|
DE9P
|
7443-0097-5
|
|
|
| Cal
Controls |
CALogix |
RS-485 |
RJ45 |
7443-0143-5 |
7446-0143-5 |
7444-0143-5
|
| Compumotor |
6K and 6000
Series |
RS-232 |
DE9S |
7443-0063-5 |
|
7444-0063-5 |
| Control Microsystems |
SCADAPack
Series |
RS-232 |
DE9S |
7443-0051-5 |
7446-0051-5 |
7444-0051-5 |
| RS-485 |
Leads |
7443-0052-5 |
7446-0052-5 |
7444-0052-5
|
| SCADAPack 32 |
RS-232 |
RJ-45 |
7443-0137-5 |
7446-0137-5 |
7444-0137-5 |
| Danaher Motion
|
Controllers
|
RS-232
|
RJ-12
|
|
7446-0174-5
|
|
| Control Technology Corporation (CTC) |
Series 2200-2800
Automation Controllers, Blue Fusion |
RS-232 |
RJ-12 |
7443-0104-5 |
|
7444-0104-5 |
| Series 2200-2800
Automation Controllers, Blue Fusion |
RS-232 |
RJ-11 |
Instructions |
|
Instructions |
| Copley |
Xenus |
RS-232 |
RJ-12 |
Instructions |
|
Instructions |
| Delta
Products |
DVP Series |
RS-232 |
Mini DIN 8 Pin |
7443-0094-5 |
7446-0094-5 |
7444-0094-5 |
| Electric
Motor Systems |
See
Yaskawa |
|
|
|
Emerson Motion Control (Control
Techniques) |
Axima
Controllers, EN Drives, Epsilon Drives |
RS-232 |
DE9P |
7443-0038-5 |
7446-0038-5 |
7444-0038-5 |
| RS-485 |
DE9P |
7443-0045-5 |
7446-0045-5 |
7444-0045-5
|
| Unidrive SP |
RS-485 |
RJ-45 |
7443-0139-5 |
7446-0139-5 |
7444-0139-5
|
| Entertron Industries |
SK1600-R-SA,
Smart-PAK, Smart-PAK Plus, Elite 2000 |
RS-232 |
Leads |
Instructions |
7446-0053-5 |
Instructions |
| RS-485 |
Leads |
7443-0054-5 |
7446-0054-5 |
7444-0054-5
|
|
Eurotherm
|
Mini 8
|
RS-232
|
RJ-12
|
Instructions
|
|
|
|
Festo
|
FEC Series
|
RS-232
|
DE9P
|
|
7446-0178-5
|
|
|
Fisher |
Floboss |
RS-232 |
Leads |
7443-0146-5 |
|
7444-0146-5 |
| RS-485 |
Leads |
Instructions |
|
Instructions
|
| Galil |
DMC Series |
RS-232 |
DE9S |
7443-0132-5 |
|
7444-0132-5 |
| GE
Fanuc |
Series 90 |
RS-485 |
DA15P |
7443-0008-5 |
7446-0008-5 |
7444-0008-5
|
| Series 90 (CPU351 or
CPU352) |
RS-232 |
RJ12 |
7443-0079-5 |
7446-0079-5 |
7444-0079-5 |
| VersaMax |
RS-232 |
DE9P |
7443-0050-5 |
|
7444-0050-5 |
| RS-232 |
RJ45 |
7443-0087-5 |
|
7444-0087-5 |
| RS-485 |
DA15P |
7443-0008-5 |
7446-0008-5 |
7444-0008-5
|
| VersaMax Micro |
RS-232 |
RJ45 |
|
7446-0087-5 |
|
| CMM311 Port 1
(90-30) |
RS-232 |
DB25P |
7443-0028-5 |
|
7444-0028-5 |
| CMM311 Port 2
(90-30) (Connects directly to controller) |
RS-232 |
DB25P |
7443-0029-5 |
|
7444-0029-5 |
| RS-485 |
DB25P |
7443-0030-5 |
|
7444-0030-5
|
| Giddings & Lewis |
PiC Family |
RS-232 |
Leads |
Instructions |
Instructions |
Instructions |
| Hitachi |
H Series |
RS-232 |
DA15P |
Instructions |
|
Instructions |
| Micro-EH Series |
RS-232 |
RJ-45 |
7443-0148-5 |
7446-0148-5 |
7444-0148-5 |
| Idec |
Micro³ |
RS-485 |
Mini DIN 8 Pin |
7443-0026-5 |
7446-0026-6 |
7444-0026-5
|
| RS-232 (Port 1 or Port 2
on RS232 module) |
Mini DIN 8 Pin |
7443-0152-5 |
7446-0152-5 |
7444-0152-5 |
| Micro³C,
OpenNet |
RS-485 |
Leads |
7443-0027-5 |
7446-0027-5 |
7444-0027-5
|
| MicroSmart |
RS-232 (Port 1 or Port 2
on RS232 module) |
Mini DIN 8 Pin |
7443-0153-5 |
7446-0153-5 |
7444-0153-5 |
| Industrial Control Links |
ICL
Series |
RS-232 |
DE9S |
7443-0056-5 |
7446-0056-5 |
7444-0056-5 |
| RS-485 |
Leads |
7443-0054-5 |
7446-0054-5 |
7444-0054-5
|
| Industrial
Indexing Systems |
Emerald
EMC-2000 |
RS-232 |
RJ12 |
Instructions |
|
Instructions |
| International Parallel Machines |
IP3416 |
RS-232 |
DE9P |
Instructions |
Instructions |
Instructions |
| RS-422 |
DE9P |
Instructions |
|
Instructions
|
| RS-485, 4-wire |
DE9P |
|
Instructions |
|
| Keyence |
KV Series |
RS-232 |
RJ11 or RJ12 |
7443-0003-5 |
7446-0003-5 |
7444-0003-5 |
| Koyo |
DL05, DL06, DL105, DL205
(all CPUs) |
RS-232 |
RJ-12 |
7443-0032-5 |
7446-0032-5 |
7444-0032-5 |
| DL06 (All CPUs, Port
2) |
RS-422 |
15P SVGA |
7443-0147-5 |
7446-0147-5 |
7444-0147-5
|
| DL205 (D2-250
CPU) |
RS-232 |
15P SVGA |
7443-0039-5 |
7446-0039-5 |
7444-0039-5 |
| DL305 (D3-330 CPU,
D3-232-DCU) |
RS-232 |
DB25P |
7443-0010-5 |
|
7444-0010-5 |
| DL305 (D3-350
CPU) |
RS-232 |
DB25P |
7443-0010-5 |
|
7444-0010-5 |
| RS-232 |
RJ12 |
7443-0032-5 |
7446-0032-5 |
7444-0032-5 |
| DL405 (all CPUs, Port
0) |
RS-232 |
DA15P |
7443-0012-5 |
7446-0012-5 |
7444-0012-5 |
| DL405 (all
CPUs, Port 1) |
RS-232 |
DB25P |
7443-0034-5 |
7446-0034-5 |
7444-0034-5 |
| RS-422 |
DB25P |
7443-0036-5 |
|
7444-0036-5
|
| RS-485,
4-wire |
DB25P |
|
7446-0036-5 |
|
| DL405 (D4-450 CPU, Port
2) |
RS-232 |
RJ12 |
7443-0032-5 |
7446-0032-5 |
7444-0032-5 |
| DL405 (D4-450 CPU, Port
3) |
RS-422 |
DB25P |
7443-0037-5 |
7446-0037-5 |
7444-0037-5
|
| DL405 Series
D4-DCM |
RS-422 |
DB25P |
7443-0042-5 |
7446-0042-5 |
7444-0042-5
|
| Matsushita |
See
Panasonic |
|
|
|
| Mitsubishi |
AJ71 Module |
RS-422 |
Leads |
7443-0084-5 |
|
7444-0084-5
|
| RS-485,
4-wire |
Leads |
|
7446-0084-5 |
|
| FX 1N-232BD, FX2N-232BD,
AJ1UC24 Com Modules |
RS-232 |
DE9 |
7443-0154-5 |
7446-0154-5 |
7444-0154-5 |
| FX, FX2C |
RS-422 |
DB25P |
7443-0013-5 |
|
7444-0013-5
|
| RS-485,
4-wire |
DB25P |
|
7446-0013-5 |
|
| FX0, FX0N, FX0S,
FX2N, FX1S, FX1N, FX2NC, FX1S,
FX1N, FX2NC |
RS-422 |
Mini DIN 8 Pin |
7443-0024-5 |
|
7444-0024-5
|
| RS-485,
4-wire |
Mini DIN 8 Pin |
|
7446-0024-5 |
|
| Q Series |
RS-232 |
Mini DIN 6 Pin |
Instructions |
Instructions |
Instructions |
| Modicon (Schneider Electric) |
984 Series, Compact, TSX
Quantum |
RS-232 |
DE9P |
7443-0009-5 |
7446-0009-5 |
7444-0009-5 |
| Micro,
Momentum, Compact |
RS-232 |
RJ45 |
7443-0033-5 |
7446-0033-5 |
7444-0033-5 |
| TSX3710 |
RS-485 |
Mini DIN 8 Pin |
7443-0081-5 |
7446-0081-5
|
7444-0081-5
|
| TSX Nano
(Modbus) |
RS-485 |
Leads |
7443-0027-5 |
7446-0027-5
|
7444-0027-5
|
| Twido
|
RS-232 |
Mini DIN 8
Pin |
Instructions |
Instructions
|
Instructions |
| RS-485 |
Mini DIN 8
Pin |
Instructions |
Instructions
|
Instructions
|
| RS-485 |
Leads |
7443-0142-5 |
7446-0142-5
|
7444-0142-5
|
| Moeller |
PS4 Series |
RS-232 |
8-Pin |
Instructions |
|
Instructions |
| Motorola RTU |
MOSCAD,
MOSCAD Lite |
RS-232 |
RJ45 |
7443-0074-5 |
7446-0074-5
|
7444-0074-5 |
| RS-485 |
Handset |
Instructions |
Instructions
|
Instructions
|
| NAiS |
See
Panasonic |
|
|
|
| Omron |
C20H, C28H,
C40H |
RS-232 |
DE9P |
7443-0014-5 |
7446-0014-5
|
7444-0014-5 |
| C20K, C28K,
C40K, C60K, C200H, C200H+ |
RS-232 |
DB25P |
7443-0016-5 |
7446-0016-5
|
7444-0016-5 |
| RS-422 |
DE9P |
7443-0017-5 |
7446-0017-5
|
7444-0017-5
|
| C200HS, CPM1, SRM1, CQM1,
CS/CJ Series |
RS-232 |
DE9P |
7443-0015-5 |
7446-0015-5
|
7444-0015-5 |
| CJ1/CS1Ethernet Crossover
|
RJ-45
|
RJ-45
|
|
7446-0181-5
|
|
| Panasonic |
FP0, FPM |
RS-232 |
Mini DIN 5 Pin |
7443-0043-5 |
7446-0043-5
|
7444-0043-5
|
| FP1 |
RS-422 |
Hirose 8P |
Instructions |
|
Instructions
|
| RS-485,
4-wire |
Hirose 8P |
|
Instructions |
Instructions
|
| FP2 |
RS-232 |
Mini DIN 5 Pin |
7443-0043-5 |
7446-0043-5
|
7444-0043-5
|
| RS-232 |
DE9P |
7443-0092-5 |
7446-0092-5
|
7444-0092-5 |
| FP3 |
RS-422 |
DA15P |
Instructions |
|
Instructions
|
| RS-485,
4-wire |
DA15P |
|
Instructions |
Instructions
|
| Parker
Hannifin |
See
Compumotor |
|
|
|
| QuickSilver |
SilverMax |
RS-232 |
DE9P |
7443-0050-5 |
|
7444-0050-5 |
| SAF
Drives |
OEM SAFphire, CA418
Processor Card |
RS-232 |
DE9S |
7443-0051-5 |
7446-0051-5
|
7444-0051-5 |
| Saftronics |
See
Yaskawa |
|
|
|
| Samsung |
NX7
Series |
RS-232
|
RJ45 |
7443-0160-5 |
7446-0160-5
|
7444-0160-5 |
| RS-232
|
DE9P |
7443-0158-5 |
7446-0158-5
|
7444-0158-5 |
| RS-485 |
RJ45 (COM2) |
Instructions |
|
Instructions |
| SPC10 |
RS-485 |
Mini Din 8 Pin |
Instructions |
|
Instructions |
| Schneider
Electric |
See
Modicon and Telemecanique |
|
|
|
| Siemens |
S7-200 Series |
RS-485, 2-wire |
DE9P |
7443-0025-5 |
7446-0025-5
|
7444-0025-5
|
S7-300 Series Note 2 |
RS-232 |
DE9S |
7431-0107 |
7431-0108
|
7431-0107 |
| SIMATIC
TI505 |
RS-232 |
DB25 |
7443-0020-5 |
|
7444-0020-5 |
| RS-232 |
DE9S |
7443-0019-5 |
|
7444-0019-5 |
| RS-422 |
DE9P |
Instructions |
|
Instructions
|
| SIMATIC TI555
CPU/545-1102 |
RS-422 |
DE9P |
Instructions |
|
Instructions
|
| SIXNET |
SIXTRAK Gateways,
VersaTrak RTUs |
RS-232 |
DE9S |
7443-0056-5 |
7446-0056-5
|
7444-0056-5 |
| IPM
Series |
RS-232 |
RJ45 |
7443-0136-5 |
7446-0136-5
|
7444-0136-5 |
| RS-485 |
Leads |
7443-0129-5 |
7446-0129-5
|
7444-0129-5
|
| Tecnologic
Controllers |
Loop Controllers TL, TD,
TLK Series |
RS-485 |
Leads |
Instructions |
|
Instructions
|
| Telemecanique (Schneider Electric) |
TSX Nano
(Modbus) |
RS-485 |
Leads |
7443-0027-5 |
7446-0027-5
|
7444-0027-5
|
| Texmate |
TEX-ICC400 |
RS232 |
RJ12
|
Instructions |
|
Instructions |
| RS485 |
RJ12
|
Instructions |
|
Instructions |
| Tolomatic |
Axiom |
RS-232 |
DE9S |
7443-0138-5 |
7446-0138-5
|
7444-0138-5 |
| Toshiba |
T1 |
RS-232 |
Mini DIN 8 Pin |
7443-0001-5 |
|
7444-0001-5 |
| T2, T3 |
RS-232 |
DE9P |
7443-0002-5 |
7446-0002-5
|
7444-0002-5 |
| Triangle
Research |
T100MD+ |
RS-232 |
DE9P |
7443-0050-5 |
|
7444-0050-5 |
| Trio Motion |
MC204, MC205, MC206,
MC216 Port 1 |
RS-232 |
Mini DIN 8P |
7443-0101-5 |
|
7444-0101-5 |
| MC204, MC206 Port
2 |
RS-485 |
Mini DIN 8P |
7443-0102-5 |
|
7444-0102-5
|
| MC202 Port 1, MC205,
MC216 (Port 2) via P348/349 serial to RS485 adapter |
RS-485, 4-wire |
DB25 |
Instructions |
7446-0105-5
|
Instructions
|
| Trident |
Controllers |
RS-232 |
DE9S |
7443-0127-5 |
|
7444-0127-5 |
| Wago |
System 750 |
RS-485 |
DE9P |
7443-0130-5 |
7446-0130-5
|
7444-0130-5
|
| Watlow Electric |
CAS-200,
CLS-200 |
RS-485 |
Leads |
Instructions |
|
Instructions
|
| MLS-300 |
RS-232 |
RJ12 |
Instructions |
|
Instructions |
| RS-485 |
RJ12 |
Instructions |
|
Instructions
|
| PPC-2000 |
RS-232 |
RJ11 |
Instructions |
|
Instructions |
| RS-485 |
RJ12 |
Instructions |
|
Instructions
|
| Whedco |
IMC, IMJ, S2K |
RS232 |
DE9P |
Instructions |
|
Instructions |
|
Yaskawa |
MP920,
MP930 &
MP2300 |
RS232 |
DE9P |
7443-0086-5 |
7446-0086-5
|
7444-0086-5 |
| MP940
|
RS232 |
3M MDR
|
Instructions |
Instructions
|
Instructions |
| RS485, 4-wire |
3M MDR
|
Instructions |
Instructions
|
Instructions
|
| SMC 20x0,
3010 |
RS232 |
DE9S |
7443-0132-5 |
|
7444-0132-5 |
|
FSP Sigma
|
RS232
|
3M MDR
|
Instructions
|
|
Instructions
|
| YET |
Xtra Drive |
RS232 |
3M
MDR |
7443-0149-5 |
|
7444-0149-5 |
- Note 1:
- The SLC 5/01 and SLC 5/02 require the use
of an Allen Bradley Communications Interface Module.
- Note 2:
- The Siemens S7-300 requires the use of an
HMI adapter (Maple P/N 7431-0107) to
allow communications to a Silver Series OIT. Please
contact Maple Systems for pricing information and
lead time.
|